Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling.
Triple wall stove pipe clearance.
Those clearance spacings are normally found in at least two locations.
A class a chimney pipe requires less clearance than a single or double wall stovepipe which is only intended for use within the same room as the stove.
So 1 stop using the thing until you solve this.
For example a single wall stove pipe requires 18 inches of clearance from ceilings or walls.
Most of the double wall stove pipe allows for 6 clearance from wall combustibles and 8 from ceiling combustibles.
018 aluminized steel intermediate liner.
All stove chimney pipe is chosen and classified by the inside diameter.
Class a triple wall chimney systems are designed for easy installation feature a fire safe design to protect both the chimney the building.
Stove pipe is made in single and double wall versions.
Triple wall class a pipe is the preferred solution for homeowners installing their own system due to its increased margin of safety.
Ul listed to ul 103ht mh7399 please note.
Once these clearances are met you must convert your stove pipe to class a chimney pipe for proper venting of your stove.
The chimney could very well be ht or class a generic not a fireplace chimney but most of us have only seen such chimney with 2 clearances.
To 6 in the closest clearance to a wall of any connector pipe.
This boosts stove efficiency by exhausting hot flue gases easily and efficiently.
Listing double and triple wall insulated pipe is listed as class a vent pipe and must meet either ul standard 103 or 103ht.
Our class a tiple wall chimney systems stay cool on the outside while providing a hot draft on the inside.
2 remove some wood and there will be a label on the chimney itself this states the model and the clearances.
Ul standard 103 requires pipe capable of safety operating with an internal temperature of 1 000.
Materials and construction 016 430 stainless steel outer wall or 018 galvanized steel outer wall.
Chimney pipe also is made in two types double wall and triple wall.
Double wall stove pipe on the other hand requires only 8 inches of clearance from the ceiling and 6 inches from a wall.
016 430 stainless.
Notes to the metal chimney fire clearance table above.
As listed where shown in the table above means that the acceptable fire clearance distances for those chimney types must match or comply with the manufacturer s instructions.
Dvl s double wall air insulated design reduces clearances to combustibles from 18 in.
The installation instructions for the specific flue vent connector or metal.
Dvl improves stove performance by maintaining high flue gas temperatures for a strong steady draft.